EASCO SM5 Series

Low Pressure
Steam and Hot Water "Thru-the-Door" Boiler
20150 Boiler Horsepower

Manufactured by A. L. Eastmond & Sons, Inc.

Low Pressure
Modified Scotch Boilers
20-150 Boiler Horsepower

EASCO Series SM5, Modified Scotch Marine, Horizontal Firetube 3-Pass Waterbacked Combustion Systems are manufactured for use in low-pressure steam (15 PSIG) or hot-water (30 to 60 PSIG standard) applications, providing for efficient operation and low cost maintenance.

Operating Controls

STEAM [15 PSIG]

Steam pressure gauge Combination LWCO and pump controller, water column with gauge glass, tri-cocks Auxiliary LWCO manual reset Operating pressure control High limit manual reset pressure control Modulating pressure control ASME safety relief valve(s)

WATER [30 PSIG]

Pressure/temperature gauge Manual reset LWCO Operating temperature control High limit manual reset temperature control Modulating temperature control ASME safety relief valve(s)

Ordering Nomenclature

SM5-XXX-ABBB-(FEB) PBA

WHERE SM5 DESIGNATES BOILER SERIES :-XXX DESIGNATES NOMINAL BOILER HORSEPOWER :-ABBB DESIGNATES MEDIUM (A) AND PRESSURE (BBB)

S015 LOW PRESSURE STEAM 15 PSIG
W030 TO W160 WATER 30 TO 160 PSIG
S = LOW PRESSURE STEAM
W = HOT WATER
FEB = FIELD ERECTED BOILER
PBA = PACKAGED BOILER ASSEMBLY

Local EASCO Representative

FORM SM50502R00
Specifications subject to change without notice

9221 Ditmas Avenue Brooklyn, NY 11236
Tel 718-342-2220
e-mail webmaster@easco.com
www.supremeboilers.com

PACKAGED BOILER ASSEMBLY - RIGHT ELEVATION

FRONT VIEW

REAR VIEW

■ EASCO Series SM5, Steel Modified Scotch Marine Horizontal Firetube 3-Pass Waterbacked Packaged Combustion Systems are manufactured for use in low pressure steam (15 PSIG) and hot-water (30-60 PSIG standard. Up to 160 PSIG, maximum 250 degrees F, available upon request) applications, providing for efficient operation and low cost maintenance.

■ Series SM5 boilers are rated at 5 SQ FT of fireside heating surface per boiler horsepower permitting long service life, are constructed in accordance with ASME Code Section IV and fully jacketed to assure high ther- mal efficiencies utilizing 2" thick insulating material.

■ Front and rear tubesheet access doors provide for quick and easy maintenance procedures.

■ Minimum refractory material further provides reduced maintenance, repair and/or replacement costs.

■ Gas, #2 Oil, #2 Oil and Gas Combination Fuel Burning Systems are available, as indicated, to suit any applicable standard, such as UL, IRI, FM, ASME CSD-1, and particular specification requirements.

■ Designed to allow "Thru-the-Door" installation removing the need for the expense and damage of building demolition necessary with many other comparable firetube boilers.

■ EASCO welcomes inquiries and the opportunity to service your needs. Please contact our factory for additional information, options and compliance specification requirement.

Note
All dimensions are approximate and submitted for general layout purposes only. Overall dimensions may vary due to burner selection, burner components (air compressor, oil pump, control panel, etc.) and boiler trim requirements. Please contact the factory for the certified dimensional drawings.

9221 Ditmas Avenue Brooklyn, NY 11236
Tel 718-342-2220
e-mail webmaster@easco.com
www.supremeboilers.com